4.4.2 CHANGE CODE ID
To modify the Code ID, click the field next to a symbology. Then, choose your Code ID
from the pop-up window of Grid Control.
Up to two characters for Code ID can be configured for each symbology.
If "Keyboard Wedge", “Bluetooth HID” or “USB HID is the interface, Key Type and Key
Status will then become applicable. Decide whether or not to apply Key Status when
“Normal Key” is selected for Key Type.
Key Type
Key Status
Scan Code N/A
Normal Key
Add Shift
Add Left Ctrl
Add Left Alt
Add Right Ctrl
Add Right Alt
Refer to
Appendix I Grid Control.
4.4.3 CLEAR
Click this button to clear the current settings. Default settings will be loaded. That is, the
Code ID settings are empty.